<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>P/T curve lezen en interpreteren &#8211; GF - Expert Engineering Zone</title>
	<atom:link href="https://gf-eez.com/fr/tag/p-t-curve-lezen-en-interpreteren-fr/feed/" rel="self" type="application/rss+xml" />
	<link>https://gf-eez.com/fr/tag/p-t-curve-lezen-en-interpreteren-fr/</link>
	<description>Find solutions. Instantly. Easily.</description>
	<lastBuildDate>Mon, 30 Jan 2023 13:45:47 +0000</lastBuildDate>
	<language>fr-FR</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0</generator>

<image>
	<url>https://gf-eez.com/wp-content/uploads/2020/06/cropped-EEZ-32x32.jpg</url>
	<title>P/T curve lezen en interpreteren &#8211; GF - Expert Engineering Zone</title>
	<link>https://gf-eez.com/fr/tag/p-t-curve-lezen-en-interpreteren-fr/</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">235385683</site>	<item>
		<title>Lecture d&#8217;un diagramme ou d&#8217;une courbe de P/T</title>
		<link>https://gf-eez.com/fr/lecture-dun-diagramme-ou-dune-courbe-de-p-t/</link>
		
		<dc:creator><![CDATA[Frederik Koninckx]]></dc:creator>
		<pubDate>Thu, 19 Jan 2023 16:32:19 +0000</pubDate>
				<category><![CDATA[Techniques de mesure]]></category>
		<category><![CDATA[canalisation]]></category>
		<category><![CDATA[coube p/t]]></category>
		<category><![CDATA[Druk-temperatuur diagram of curve lezen]]></category>
		<category><![CDATA[Hoe lees je een P/T Diagram]]></category>
		<category><![CDATA[Lecture d'un diagramme pression-température]]></category>
		<category><![CDATA[Lecture d'une courbe pression-température]]></category>
		<category><![CDATA[Materialen in piping]]></category>
		<category><![CDATA[matière synthétique]]></category>
		<category><![CDATA[P/T curve lezen en interpreteren]]></category>
		<guid isPermaLink="false">https://gf-eez.com/hoe-lees-je-een-p-t-diagram-of-curve/</guid>

					<description><![CDATA[<p>Une courbe de P/T (pression/température) rend compte, pour une matière synthétique donnée, de la capacité de charge admissible sous l’effet conjugué de la pression et de la température. La courbe part de l’hypothèse d’une charge permanente, dans la perspective d’une durée de vie théorique de 25 ans. Cependant, le tracé de cette courbe correspond à &#8230;</p>
<p>L’article <a href="https://gf-eez.com/fr/lecture-dun-diagramme-ou-dune-courbe-de-p-t/">Lecture d&#8217;un diagramme ou d&#8217;une courbe de P/T</a> est apparu en premier sur <a href="https://gf-eez.com/fr/">GF - Expert Engineering Zone</a>.</p>
]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="wp-post" data-elementor-id="3214" class="elementor elementor-3214 elementor-2667">
						<section class="elementor-section elementor-top-section elementor-element elementor-element-ffa0df5 elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="ffa0df5" data-element_type="section" data-e-type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-a7da8f2" data-id="a7da8f2" data-element_type="column" data-e-type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-0c4b0aa elementor-widget elementor-widget-text-editor" data-id="0c4b0aa" data-element_type="widget" data-e-type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p>Une <strong>courbe de P/T</strong> (pression/température) rend compte, pour une <strong>matière synthétique</strong> donnée, de la capacité de charge admissible sous l’effet conjugué de la pression et de la température. La courbe part de l’hypothèse d’une charge permanente, dans la perspective d’une durée de vie théorique de 25 ans. Cependant, le tracé de cette courbe correspond à des &#8220;conditions idéales&#8221;; en d’autres termes, les <strong>canalisations</strong> ne subissent pratiquement aucune tension mécanique due à leur montage et à leur fixation ni aucun <strong>coup de bélier</strong>. De plus, elles ne sont soumises à l’application d’aucune force extérieure, etc. </p><p>Cette courbe est également établie en partant de l’eau et de fluides dont l’influence chimique sur la matière synthétique étudiée est comparable à celle de l’eau. C’est la raison pour laquelle il faut impérativement tenir compte de l’évaluation relative à la résistance chimique lorsque l’on se penche sur la courbe de P/T (cf. coefficients d’atténuation ou derating factors): <a href="https://gf-eez.com/fr/guide-dinitiation-rapide-a-la-lecture-et-a-linterpretation-dune-table-des-resistances-chimiques/">voir volet consacré à la résistance chimique</a>). Ci-après, vous allez découvrir un exemple concret de diagramme de P/T se rapportant au matériau constitutif d’une canalisation en PE100.</p>								</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				<section class="elementor-section elementor-top-section elementor-element elementor-element-7efd68d elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="7efd68d" data-element_type="section" data-e-type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-54af6dd" data-id="54af6dd" data-element_type="column" data-e-type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-7bd3eea elementor-widget elementor-widget-image" data-id="7bd3eea" data-element_type="widget" data-e-type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img fetchpriority="high" decoding="async" width="1024" height="487" src="https://gf-eez.com/wp-content/uploads/2020/09/GRAFIEK-PT-FR-1024x487.jpg" class="attachment-large size-large wp-image-3827" alt="" srcset="https://gf-eez.com/wp-content/uploads/2020/09/GRAFIEK-PT-FR-1024x487.jpg 1024w, https://gf-eez.com/wp-content/uploads/2020/09/GRAFIEK-PT-FR-300x143.jpg 300w, https://gf-eez.com/wp-content/uploads/2020/09/GRAFIEK-PT-FR-768x365.jpg 768w, https://gf-eez.com/wp-content/uploads/2020/09/GRAFIEK-PT-FR-1536x730.jpg 1536w, https://gf-eez.com/wp-content/uploads/2020/09/GRAFIEK-PT-FR-2048x974.jpg 2048w, https://gf-eez.com/wp-content/uploads/2020/09/GRAFIEK-PT-FR-370x176.jpg 370w" sizes="(max-width: 1024px) 100vw, 1024px" />															</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				<section class="elementor-section elementor-top-section elementor-element elementor-element-bb8bd37 elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="bb8bd37" data-element_type="section" data-e-type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-944c8ae" data-id="944c8ae" data-element_type="column" data-e-type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-7d77fca elementor-widget elementor-widget-text-editor" data-id="7d77fca" data-element_type="widget" data-e-type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p>Dans le cas présent, nous faisons la distinction entre trois courbes respectivement associées à un coefficient de sécurité (design factor) particulier:</p><ul><li>C = 1,25 pour toute application au sein d’une installation de distribution d’eau potable</li><li>C = 1,25 pour toute application industrielle générale</li><li>C = 2,00 pour toute application résolument chimique</li></ul><p>Prenons par exemple le diagramme <b>PE100 SDR11</b> et considérons une application comportant le <strong>transport d’un produit chimique</strong> (situation correspondant à la courbe dont le coefficient de sécurité s’élève à 2,00), en supposant que la résistance chimique a été vérifiée, on observe que, pour une température du fluide portée à 40 °C, la pression de fonctionnement admissible s’élève encore à 7,5 bars. </p><p>En reprenant le même exemple, on observe inversement que pour une pression de fonctionnement portée à 9 bars, la température maximale admissible s’élève à 27 °C pour ce fluide. En admettant que, conformément à la <b>liste des résistances chimiques</b>, un produit chimique déterminé requière l’application d’un coefficient d’atténuation (derating factor), c’est à <b>la courbe de P/T</b> qu’il y a lieu de l’appliquer; l’abaissement de la courbe qui en résulte correspond à l’application du coefficient correspondant. <span style="letter-spacing: -0.01em;">Dans l’exemple qui précède, on observe que, pour une température du fluide portée à 40 °C dans une </span><b style="letter-spacing: -0.01em;">canalisation en PE100</b><span style="letter-spacing: -0.01em;"> transportant un produit chimique nécessitant l’application d’un coefficient d’atténuation 1,2, la pression de fonctionnement maximale admissible n’est plus égale à 7,5 bars, mais à 7,5 bars / 1,2 = 6,25 bars.</span></p>								</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				</div>
		<p>L’article <a href="https://gf-eez.com/fr/lecture-dun-diagramme-ou-dune-courbe-de-p-t/">Lecture d&#8217;un diagramme ou d&#8217;une courbe de P/T</a> est apparu en premier sur <a href="https://gf-eez.com/fr/">GF - Expert Engineering Zone</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">3214</post-id>	</item>
	</channel>
</rss>
