<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>détection et origine de fuite &#8211; GF - Expert Engineering Zone</title>
	<atom:link href="https://gf-eez.com/fr/tag/detection-et-origine-de-fuite/feed/" rel="self" type="application/rss+xml" />
	<link>https://gf-eez.com/fr/tag/detection-et-origine-de-fuite/</link>
	<description>Find solutions. Instantly. Easily.</description>
	<lastBuildDate>Fri, 27 Jan 2023 09:51:06 +0000</lastBuildDate>
	<language>fr-FR</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://gf-eez.com/wp-content/uploads/2020/06/cropped-EEZ-32x32.jpg</url>
	<title>détection et origine de fuite &#8211; GF - Expert Engineering Zone</title>
	<link>https://gf-eez.com/fr/tag/detection-et-origine-de-fuite/</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">235385683</site>	<item>
		<title>Origine d&#8217;une fuite affectant un processus chimique</title>
		<link>https://gf-eez.com/fr/origine-fuite-liquide-affectant-un-processus-chimique/</link>
		
		<dc:creator><![CDATA[David Boonen]]></dc:creator>
		<pubDate>Fri, 20 Jan 2023 07:51:15 +0000</pubDate>
				<category><![CDATA[Références]]></category>
		<category><![CDATA[Techniques de mesure]]></category>
		<category><![CDATA[détection et origine de fuite]]></category>
		<category><![CDATA[eau pollué]]></category>
		<category><![CDATA[fuite affectant un processus chimique]]></category>
		<category><![CDATA[home]]></category>
		<category><![CDATA[hydrostatische niveaumeting]]></category>
		<category><![CDATA[industrie chimique]]></category>
		<category><![CDATA[Lek in chemisch proces]]></category>
		<category><![CDATA[Lekkende niveaumeting]]></category>
		<category><![CDATA[liquide corrosif]]></category>
		<category><![CDATA[oorzaak lek opzoeken]]></category>
		<category><![CDATA[pvdf]]></category>
		<category><![CDATA[sonde]]></category>
		<guid isPermaLink="false">https://gf-eez.com/oorzaak-van-een-lek-in-chemisch-proces/</guid>

					<description><![CDATA[<p>Lekken in de chemische industrie duiden altijd op gevaar. Lekken opsporen, de oorzaak achterhalen en vooral voorkomen dat hetzelfde probleem zich nog eens voordoet, dat is de opdracht van de procesingenieur.</p>
<p>L’article <a href="https://gf-eez.com/fr/origine-fuite-liquide-affectant-un-processus-chimique/">Origine d&#8217;une fuite affectant un processus chimique</a> est apparu en premier sur <a href="https://gf-eez.com/fr/">GF - Expert Engineering Zone</a>.</p>
]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="wp-post" data-elementor-id="3206" class="elementor elementor-3206 elementor-2386">
						<section class="elementor-section elementor-top-section elementor-element elementor-element-1212b91d elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="1212b91d" data-element_type="section" data-e-type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-3105f7b7" data-id="3105f7b7" data-element_type="column" data-e-type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-459d9ee5 elementor-widget elementor-widget-text-editor" data-id="459d9ee5" data-element_type="widget" data-e-type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p>Dans <b>l’industrie chimique</b>, aucune <b>fuite </b>n’est sans risque. C&#8217;est pour cela que la mission de <b>l&#8217;ingénieur de production</b> est de détecter toute fuite éventuelle, en découvrir l&#8217;origine et surtout prévenir la réitération du problème identifié. Cet article traite de la cause d’une fuite de liquide et de la résolution du problème.</p>								</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				<section class="elementor-section elementor-top-section elementor-element elementor-element-4f28a2b elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="4f28a2b" data-element_type="section" data-e-type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-b4c8e75" data-id="b4c8e75" data-element_type="column" data-e-type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-0899870 elementor-widget elementor-widget-image" data-id="0899870" data-element_type="widget" data-e-type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img fetchpriority="high" decoding="async" width="768" height="998" src="https://gf-eez.com/wp-content/uploads/2023/01/fuite.jpg" class="attachment-medium_large size-medium_large wp-image-5573" alt="fuite liquide affectant un processus chimique industrie" srcset="https://gf-eez.com/wp-content/uploads/2023/01/fuite.jpg 768w, https://gf-eez.com/wp-content/uploads/2023/01/fuite-231x300.jpg 231w, https://gf-eez.com/wp-content/uploads/2023/01/fuite-370x481.jpg 370w" sizes="(max-width: 768px) 100vw, 768px" />															</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				<section class="elementor-section elementor-top-section elementor-element elementor-element-76ca206 elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="76ca206" data-element_type="section" data-e-type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-e01d732" data-id="e01d732" data-element_type="column" data-e-type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-9ff87cd elementor-widget elementor-widget-text-editor" data-id="9ff87cd" data-element_type="widget" data-e-type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<h2><strong>Configuration</strong></h2><p>Ces capteurs ont été installés sur le site d&#8217;une entreprise spécialisée dans le<b> traitement d’effluents très pollués</b>. Sur la photo, on aperçoit un <b>dispositif de mesure du niveau hydrostatique</b> (tête jaune assortie d’une bride). Les données recueillies par cet équipement s’affichent sur l’écran numérique.</p><p>Une fuite est apparue lors de la mise en service de l’installation ; le fluide acheminé à travers le dispositif de mesure du niveau hydrostatique a commencé à suinter et à se répandre sur le sol. Comme toute mise en service d’une nouvelle installation, celle-ci s’est déroulée en plusieurs phases et dans des conditions de sécurité satisfaisantes en utilisant un fluide sans danger. Si cette fuite s’était manifestée en cours d’exploitation, la libération d’<b>une eau de processus très polluée</b> aurait fait courir le risque d’une <b>pollution atmosphérique</b>. Par conséquent, il était capital de trouver une solution permettant de prévenir tout risque de manifestation future d’une fuite comparable.</p><p><strong style="text-align: inherit; color: #29293a; font-family: 'Roboto Condensed', sans-serif; font-size: 30px; letter-spacing: -0.01em;">Symptômes d&#8217;une fuite de liquide</strong></p><p>Fuite d’un <b>liquide très corrosif</b> à la hauteur de la sonde. Parfaitement visible de l’extérieur, l’effet de la fuite se manifeste sous la forme de projections de teinte orange qui corrodent le matériel.</p><p>Le démontage de la <b>sonde </b>révèle que le capteur et l’électronique sont corrodés. L’origine de la fuite ne fait aucun doute. Le serrage erroné de l’écrou a permis à l’effluent pollué par la présence d’acides et de bases de suinter le long du filet et de causer de sérieux dommages à l’extérieur du dispositif.</p>								</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				<section class="elementor-section elementor-top-section elementor-element elementor-element-4a78770 elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="4a78770" data-element_type="section" data-e-type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-cbdd14f" data-id="cbdd14f" data-element_type="column" data-e-type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-0c1bde8 elementor-widget elementor-widget-image" data-id="0c1bde8" data-element_type="widget" data-e-type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img decoding="async" width="1024" height="762" src="https://gf-eez.com/wp-content/uploads/2023/01/fuite-2.jpg" class="attachment-large size-large wp-image-5576" alt="photo d&apos;une fuite liquide affectant un processus chimique industrie" srcset="https://gf-eez.com/wp-content/uploads/2023/01/fuite-2.jpg 1024w, https://gf-eez.com/wp-content/uploads/2023/01/fuite-2-300x223.jpg 300w, https://gf-eez.com/wp-content/uploads/2023/01/fuite-2-768x572.jpg 768w, https://gf-eez.com/wp-content/uploads/2023/01/fuite-2-370x275.jpg 370w" sizes="(max-width: 1024px) 100vw, 1024px" />															</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				<section class="elementor-section elementor-top-section elementor-element elementor-element-9189b45 elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="9189b45" data-element_type="section" data-e-type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-0c281ac" data-id="0c281ac" data-element_type="column" data-e-type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-18f5204 elementor-widget elementor-widget-text-editor" data-id="18f5204" data-element_type="widget" data-e-type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<h2><strong> Solutions envisageables</strong></h2><p>Premier réflexe : tout remplacer et serrer correctement la pièce concernée. Cependant, les experts se sont également mis en quête d’une solution qui exclue définitivement la manifestation future de telles fuites. Cette solution réside dans la fabrication de <b style="color: #5b5b60; font-family: Nunito, sans-serif; font-size: 18px; letter-spacing: -0.01em;">joints d’étanchéité </b><span style="color: #5b5b60; font-family: Nunito, sans-serif; font-size: 18px; letter-spacing: -0.01em;">sur mesure.</span></p><p>Dans un premier temps, les experts ont déposé le dispositif standard de mesure du niveau dont le montage s’effectuait à l’aide d’<b>un raccord trois pièces</b>. Ensuite, ils ont procédé au soudage de la sonde à même la bride de fixation. Cette opération réduit à néant le risque de fuite et l’installateur ne risque plus de commettre la même erreur.</p><p>Le matériau utilisé revêt une importance majeure dans cette application. Les sondes sont exécutées en<b> fluorure de polyvinylidène</b> <b>(PVDF)</b>, un<b> polymère thermoplastique non réactif</b> que l’on utilise habituellement dans le cadre d’applications critiques telles que celles que l’on rencontre dans la<b> métallurgie, la pétrochimie et l’industrie chimique</b>. Le produit sera préalablement assemblé dans les ateliers de <b>GF Belgique.</b></p>								</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				<section class="elementor-section elementor-top-section elementor-element elementor-element-d671247 elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="d671247" data-element_type="section" data-e-type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-b385899" data-id="b385899" data-element_type="column" data-e-type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-383f49b elementor-widget elementor-widget-image" data-id="383f49b" data-element_type="widget" data-e-type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img decoding="async" width="1024" height="578" src="https://gf-eez.com/wp-content/uploads/2023/01/fuite-3.jpg" class="attachment-large size-large wp-image-5610" alt="sonde de pression pour éviter fuite de liquide" srcset="https://gf-eez.com/wp-content/uploads/2023/01/fuite-3.jpg 1024w, https://gf-eez.com/wp-content/uploads/2023/01/fuite-3-300x169.jpg 300w, https://gf-eez.com/wp-content/uploads/2023/01/fuite-3-768x434.jpg 768w, https://gf-eez.com/wp-content/uploads/2023/01/fuite-3-370x209.jpg 370w" sizes="(max-width: 1024px) 100vw, 1024px" />															</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				<section class="elementor-section elementor-top-section elementor-element elementor-element-1a08c1b elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="1a08c1b" data-element_type="section" data-e-type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-876f8d8" data-id="876f8d8" data-element_type="column" data-e-type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-4eded31 elementor-widget elementor-widget-text-editor" data-id="4eded31" data-element_type="widget" data-e-type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p><a href="https://gf-eez.com/fr/quels-tubes-choisir-pour-transport-liquides-corrosifs/">Cliquez ici pour en savoir plus sur la sélection des matériaux adaptés aux processus chimiques.</a></p>								</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				<section class="elementor-section elementor-top-section elementor-element elementor-element-4a25736 elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="4a25736" data-element_type="section" data-e-type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-b5cd25a" data-id="b5cd25a" data-element_type="column" data-e-type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-bd24d64 elementor-widget elementor-widget-image" data-id="bd24d64" data-element_type="widget" data-e-type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img loading="lazy" decoding="async" width="1024" height="535" src="https://gf-eez.com/wp-content/uploads/2023/01/fuite-4.jpg" class="attachment-large size-large wp-image-5613" alt="écran de contrôle de pression pour éviter fuite de liquide" srcset="https://gf-eez.com/wp-content/uploads/2023/01/fuite-4.jpg 1024w, https://gf-eez.com/wp-content/uploads/2023/01/fuite-4-300x157.jpg 300w, https://gf-eez.com/wp-content/uploads/2023/01/fuite-4-768x401.jpg 768w, https://gf-eez.com/wp-content/uploads/2023/01/fuite-4-370x193.jpg 370w" sizes="(max-width: 1024px) 100vw, 1024px" />															</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				</div>
		<p>L’article <a href="https://gf-eez.com/fr/origine-fuite-liquide-affectant-un-processus-chimique/">Origine d&#8217;une fuite affectant un processus chimique</a> est apparu en premier sur <a href="https://gf-eez.com/fr/">GF - Expert Engineering Zone</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">3206</post-id>	</item>
	</channel>
</rss>